[email protected] +86-0371 61288078

UL 854 aluminum conductor service entrance cable 12AWG

Products , 2-2-2 AWG, Stranded, Type SE Style R Aluminum .

Products , 2-2-2 AWG, Stranded, Type SE Style R Aluminum .

Conductors:Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836.Insulation:High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2.Conductor Jacket:A tough, polyamide nylon outer covering per UL

Get Price >>
CME - Type SEU, (Service Entrance Cable), XLPE Insulated .

CME - Type SEU, (Service Entrance Cable), XLPE Insulated .

CME Wire and Cable, Inc. was established in the US in 1994 as a subsidiary of Viakable to serve customers in the US and Canada. Through its three Divisions and four strategically located distribution centers, CME serves its customers in Residential, Commercial,

Get Price >>
UL 854 : UL Standard for Safety Service-Entrance Cables

UL 854 : UL Standard for Safety Service-Entrance Cables

These cables are for the service-entrance and other (NEC) uses described in 1.4 ?C 1.8. In a multiple-conductor cable that is other than submersible-pump cable and does not have a grounding conductor it is appropriate to have one circuit conductor without insulation.

Get Price >>
12 AWG Solar PV Wire ? Cut To Length, Wire & Cable Your

12 AWG Solar PV Wire ? Cut To Length, Wire & Cable Your

Stranded annealed copper conductors. Sunilight resistant Cross-Linked Polyethelene (XLP) insulation -40??C to +90??C. Standards: ASTM B8 Listed as type USE-2 per UL 854 Listed as type RHH/RHW-2 per UL 44 Listed as type PV per UL 4703 . Specifications*: Size: 12 AWG Number of Strands: 7 Volaltage: 600V Insulation Thickness (Conductor): 0.060 inches

Get Price >>
China Urd Cable with Aluminum 1350 Conductor XLPE .

China Urd Cable with Aluminum 1350 Conductor XLPE .

UL 854 Type Service Entrance Cable Style, Service Entrance Cable, UL854 Use-2 Al Cable manufacturer / supplier in China, offering Urd Cable with Aluminum 1350 Conductor XLPE Insulation, UL854 Auminum Ser-AA-8000, XLPE, 2 X 8 + 8 AWG, 600V, Concentric Cable, UL854 Auminum Ser-AA-8000, XLPE, 2 X 2 + 2 AWG, 600V, Concentric Cable and so on.

Get Price >>
Products , 2-2 AWG, Stranded, Type SE Style U Aluminum .

Products , 2-2 AWG, Stranded, Type SE Style U Aluminum .

Conductors:Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836.Insulation:High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2.Conductor Jacket:A tough, polyamide nylon outer covering per UL

Get Price >>
China Power Cable, Rubber Cable, Aluminum Building Wire .

China Power Cable, Rubber Cable, Aluminum Building Wire .

UL Certification Rhh Rhw Inner Core Epr Insulation CPE Sheath Rubber Dlo Cable 2000V 12AWG 3*12AWG 5*10AWG US $ 0.16/Meter UL Listed 8000 Series Aluminum Conductor Xhhw Xhhw-2 Core Underground Ud Service Entrance Cable Se/Seu/Ser

Get Price >>
UL 854 - Techstreet

UL 854 - Techstreet

Aluminum single-rated (see 1.4) Type USE or USE-2 cables containing other than solid 12, 10 or 8 AWG conductor(s) are of an EC-1350 grade aluminum alloy or a registered AA-8000 series electrical-conductor-grade aluminum alloy. In all other cables, the aluminum conductor(s) are of a registered AA-8000 electrical-conductor-grade alloy only.

Get Price >>
SE-U , XHHW-2/PVC, Service Entrance

SE-U , XHHW-2/PVC, Service Entrance

SE-U XHHW-2/PVC, Service Entrance 600 Volt Copper. . phase identified and cabled together with bare copper ground conductor. Cable core covered with flame retardant binder tape and overall grey PVC jacket. Standards. UL 44 and UL 854 ICEA S-95-658/NEMA WC70 Temperature Rated at 90??C Wet/Dry Sunlight Resistant Color Code: Black and Numbered

Get Price >>
Service Entrance Cable (SER) - HW022A , Houston Wire .

Service Entrance Cable (SER) - HW022A , Houston Wire .

Single conductors are UL Listed Types XHHW/XHHW-2. The cable is rated sunlight resistant. What is SER cable? SER cable is known as aluminum service entrance cable which is a type SE (service entrance), Style R (reinforcement tape) cable that is commonly used to deliver power from the service drop down to the meter base, and then from the meter .

Get Price >>
12 AWG UL1007/1569 Hook-Up Wire , Wire & Cable Your Way

12 AWG UL1007/1569 Hook-Up Wire , Wire & Cable Your Way

12 AWG Hookup Wire, UL 1007/1569, 65 Strand, Tinned Copper, 500 or 1000 Spool Applications: For general purpose internal wiring of electronic and electrical equipment Standards: UL 1007/1569 CSA TR-64 Specifications*: Size: 12 AWG Number of Strands: 65/30 Conductor Material: Tinned Copper Insulation Material: Polyvinyl Chloride (PVC) Voltage: 300V Temp: 80??C to 105??C Insulation Thickness .

Get Price >>
UL 854 - UL Standard for Safety Service-Entrance Cables .

UL 854 - UL Standard for Safety Service-Entrance Cables .

Single-conductor Type USE and USE-2 cables that are not larger than 4/0 AWG copper, 300 kcmil aluminum or copper-clad aluminum and multiple-conductor jacketed and coverless Type USE and USE-2 cables without an uninsulated or bare conductor are for use as Type USE or USE-2 and also are for use underground as Type UF cable would be used however .

Get Price >>
UL 854 Urd Cable 600V Aluminum Conductor Cross-Linked

UL 854 Urd Cable 600V Aluminum Conductor Cross-Linked

Tags: Service Entrance Cable, UL 854 Type Service Entrance Cable Style, UL854 Use-2 Al Cable. Next: 600V Aluminum Alloy Conductors Cable Mhf Cable; Previous: 600V Aluminum Alloy Conductor Cable Ser Cable with Cross-Linked Polyethylene (XLPE) Insulation PVC Jacket

Get Price >>
UL854 Ser Seu Xhhw-2 Cable Aluminum Alloy Conductor

UL854 Ser Seu Xhhw-2 Cable Aluminum Alloy Conductor

HUATONG Aluminum Service Entrance Cable Type SE, with rated voltage 600V, is used to transmit power from the junction box to the meter base and from the meter base to the distribution cabinet It may be used in all applications where Type SE cable is permitted.Type SE cable could be used in dry or wet environmet at the working temperature not .

Get Price >>
China UL 854 Service Entrance Cable Aluminum/Copper Type .

China UL 854 Service Entrance Cable Aluminum/Copper Type .

China UL 854 Service Entrance Cable Aluminum/Copper Type Se, Style R/U Seu 4 4 4, Find details about China Service Entrance Cable, Ser Cable from UL 854 Service Entrance Cable Aluminum/Copper Type Se, Style R/U Seu 4 4 4 - Hebei Huatong Wires & Cables Group Co., Ltd.

Get Price >>
COPPER CONDUCTOR SERVICE ENTRANCE CABLE (SEU)

COPPER CONDUCTOR SERVICE ENTRANCE CABLE (SEU)

[short] APPLICATIONS Type SE, service entrance cable is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard; however, the cable may be used in all applications where Type SE cable is permitted. SER may be used in wet or dry locations at temperatu

Get Price >>
Clemson 600 V 1350 Aluminum URD Cable ?C Single (Type

Clemson 600 V 1350 Aluminum URD Cable ?C Single (Type

? B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation." ? B-901 "Compressed round stranded Aluminum Conductors using single input wire construction." ? Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692. ? "USE-2" per UL 854 available upon request.

Get Price >>
HW021A: Service Entrance Cable SEU - Aluminum ,

HW021A: Service Entrance Cable SEU - Aluminum ,

It may be used in other branch circuits, feeders, or any application where Type SE cable is permitted by the NEC. SE cable is rated for 600V not to exceed 90C in wet or dry locations. Single conductors are UL Listed Types XHHW/XHHW-2.

Get Price >>
Service Entrance Style U (SEU) 600V - 8000 Series Aluminum .

Service Entrance Style U (SEU) 600V - 8000 Series Aluminum .

For use as to deliver electrical service from the service head to the house meter. Compact stranded 8000 series aluminum alloy conductors. XHHW-2 insulated conductors laid in parallel. Bare conductor strands are helically wound around the two parallel conductors. Glass reinforced tape is applied over the assembly.

Get Price >>
Type SEU - Service Entrance Cable, Round or Flat, Copper .

Type SEU - Service Entrance Cable, Round or Flat, Copper .

Type SEU - Service Entrance Cable Information; WesBell Electronics offers copper service entrance cables.There??s a round and a flat version of this copper cable which are known as the SER and SEU Cables. Some available awg sizes are 8, 6, 4, 3, 2, 1, 1/0, 2/0, 3/0 and 4/0.

Get Price >>
1/C AL 2000V XLPE RHH/RHW-2 Power Cable Type PV -

1/C AL 2000V XLPE RHH/RHW-2 Power Cable Type PV -

1/C AL 2000V XLPE RHH/RHW-2 Power Cable Type PV Single Conductor Photovoltaic (Type PV) Power Cable 2000 Volt Aluminum Conductor XLPE Insulation. Sizes 6AWG through 1000 kcmil. Heat, Moisture, and Sunlight Resistant RoHS. 90??C

Get Price >>
Type SEU (Sevice Entrance Cable), Copper/Aluminum

Type SEU (Sevice Entrance Cable), Copper/Aluminum

service entrance cable, to convey power from the service drop to the meter. Also in other branch circuits or feeders as permitted by NEC. Standards UL 854 Service-Entrance Cables. UL 44 Rubber-insulated wires and cables. Specifications Maximum operating voltage: ? 600 volts Maximum conductor operation temperatures: ? 90 ??C wet and dry .

Get Price >>
Service Entrance Conductors , Mike Holts Forum

Service Entrance Conductors , Mike Holts Forum

May 03, 2013??? This category covers service-entrance cable designated Type SE and Type USE for use in accordance with Article 338 of ANSI/NFPA 70, ??National Electrical Code?? (NEC). Service-entrance cable, rated 600 V, is Listed in sizes 14 AWG and larger for copper, and 12 AWG and larger for aluminum or copper-clad aluminum. The cable is designated as follows:

Get Price >>
UL - 854 Standard for Service-Entrance Cables , Standards .

UL - 854 Standard for Service-Entrance Cables , Standards .

Aluminum single-rated (see 1.4) Type USE or USE-2 cables containing other than solid 12, 10 or 8 AWG conductor(s) are of an EC-1350 grade aluminum alloy or a registered AA-8000 series electrical-conductor-grade aluminum alloy. In all other cables, the aluminum conductor(s) are of a registered AA-8000 electrical-conductor-grade alloy only.

Get Price >>