[email protected] +86-0371 61288078

ACSR conductors wire bare electrical wire for various line design

ACSR Aluminum Conductor Steel Reinforced On American

ACSR Aluminum Conductor Steel Reinforced On American

ACSR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-502 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)

Get Price >>
CONDUCTOR DATA SHEET ALUMINUM

CONDUCTOR DATA SHEET ALUMINUM

CONDUCTOR DATA SHEET ALUMINUM CONDUCTORS STEEL REINFORCED ( ACSR ) Approx. Maximum dc Code overall Rated resistance Name Steel Total Aluminium Steel diameter Aluminium Steel Total Strength at 20 oC AWG or AWG or MCM MCM TURKEY 6 13.30 2.22 15.52 8 8.39 6/1.68 1/1.68 5.04 36.5 17 54 5.28 2.1499

Get Price >>
Overhead Conductors - TransPowr? - General Cable .

Overhead Conductors - TransPowr? - General Cable .

General Cable??s extensive line of TransPowr bare overhead conductors are available in a variety of aluminum and steel stranding combinations. Learn more about our overhead conductors to find the most effective solution for your needs.

Get Price >>
ACSR - Tinde Cable

ACSR - Tinde Cable

ACSR conductors combine the light weight and good conductivity of aluminum with the high tensile strength and ruggedness of steel. In line design, this can provide higher tensions, less sag and longer span lengths than obtainable with most other types of overhead conductors. The steel strands are added as mechanical reinforcement.

Get Price >>
Petrel, ACSR Aluminum Conductor . - American Wire Group

Petrel, ACSR Aluminum Conductor . - American Wire Group

ACSR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-502 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)

Get Price >>
Bare Aluminum ACSR On American Wire Group

Bare Aluminum ACSR On American Wire Group

ACSR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-502 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)

Get Price >>
China Overhead Bare Cable, China Overhead Bare Cable .

China Overhead Bare Cable, China Overhead Bare Cable .

Overhead Bare Cable Astm B 232 Bs215-2 Iec 61089 Acsr 150/25 Mm2 Din 48204 Standard Acsr Conductor cable b Production Name ASTM 4 AWG ACSR Swanate Bare Conductor Cable for Transmission Line Standard ASTM B 232 Brand SITONG Used Power Transmission Material of Conductor 100% Soild Aluminum(6/2.67mm) Material of Steel Galvanized steel strand (1/2.67mm)

Get Price >>
ACSR/TW, Aluminum Conductor, Steel Reinforced . - CME Wire

ACSR/TW, Aluminum Conductor, Steel Reinforced . - CME Wire

Product Description. CME Wire and Cable offers ACSR/TW ?C shaped wire compact concentric-lay-stranded aluminum conductor steel reinforced ?C conductors with equal area or equal diameter designs, as compared to standard ACSR conductors, and various steel core coatings to address your application requirements for transmission and distribution projects.

Get Price >>
Bare Overhead Conductors (AAAC, AAC, ACSR, ACSR-II) -

Bare Overhead Conductors (AAAC, AAC, ACSR, ACSR-II) -

For overhead line design, this enables higher tensions to be used with less conductor sag and longer spans than would be possible with most other types of conductors. Applications Aluminum conductors, steel reinforced (ACSR) are widely used for overhead transmission and distribution lines.

Get Price >>
CONDUCTOR DATA SHEET ALUMINUM CONDUCTORS

CONDUCTOR DATA SHEET ALUMINUM CONDUCTORS

CONDUCTOR DATA SHEET ALUMINUM CONDUCTORS STEEL REINFORCED ( ACSR ) Approx. Maximum dc Code overall Rated resistance Name Steel Total Aluminium Steel diameter Aluminium Steel Total Strength at 20 oC AWG or AWG or MCM MCM TURKEY 6 13.30 2.22 15.52 8 8.39 6/1.68 1/1.68 5.04 36.5 17 54 5.28 2.1499

Get Price >>
China Aluminium Conductor Steel Reinforced ACSR Bare .

China Aluminium Conductor Steel Reinforced ACSR Bare .

1. Standard of ACSR: ACSR conductor can comply with IEC61089, ASTM B232, BS215, GB, DIN etc. 2. Construction of ACSR Conductor: According to IEC61089, cross section area of ACSR is from 16mm2 to 1250mm2, No of stranded aluminum wire and steel wire can be from Al6/1.84(mm)/Sr1/1.84 to Al84/4.35/Sr19/2.61.

Get Price >>
Overhead Bare Aluminum Conductors AAC / AAAC / ACSR /

Overhead Bare Aluminum Conductors AAC / AAAC / ACSR /

The bare conductor: ACCC, ACSS, AAC, AAAC, ACSR, AACSR, ACAR and Galvanized steel w ire, are used in overhead electrical power transmission and distribution lines with various grade voltage. Construction: Bare aluminum alloy 1350-H19 wires, concentrically stranded around a Class A galvanized coated steel core wire.

Get Price >>
477 Mcm ACSR Conductor / Overhead Electric Transmission .

477 Mcm ACSR Conductor / Overhead Electric Transmission .

electrical cables. STANDARD. Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards. CONSTRUCTION. ACSR conductors are formed by several wires of aluminium and galvanized steel, stranded in concentric layers. The wire or wires which form the core, are made of galvanized steel and the external .

Get Price >>
Overhead Conductors - TransPowr? - General Cable .

Overhead Conductors - TransPowr? - General Cable .

General Cable??s extensive line of TransPowr bare overhead conductors are available in a variety of aluminum and steel stranding combinations. Learn more about our overhead conductors to find the most effective solution for your needs.

Get Price >>
Bare Overhead Conductors - Nexans

Bare Overhead Conductors - Nexans

Stranded bare AAC conductors may be used in overhead line installations where the design parameters do not require the higher tensile strength or temperature ratings provided by ACSR, ACCR or other types of conductors. ACSR Bare Overhead Conductor Product Construction ACSR is a composite concentric-lay stranded conductor consisting of

Get Price >>
ACSR - Southwire , Overhead Transmission Conductors

ACSR - Southwire , Overhead Transmission Conductors

Aluminum Conductor Steel Reinforced Bare Applications Used as bare overhead transmission conductor and as primary and secondary distribution conductor and messenger support. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Get Price >>
Engineering Design - The Aluminum Association

Engineering Design - The Aluminum Association

Section II Bare Aluminum Wire and Cable . Chapter 3 . Engineering Design . This chapter describes lbe principal design features of . bare uninsulated conductors; however much lbat applies . to hare conductors also pertains to lbe metaUic part of in- sulated or covered conductors which are considered in

Get Price >>
Overhead Bare Aluminum Conductors AAC / AAAC / ACSR /

Overhead Bare Aluminum Conductors AAC / AAAC / ACSR /

The bare conductor: ACCC, ACSS, AAC, AAAC, ACSR, AACSR, ACAR and Galvanized steel w ire, are used in overhead electrical power transmission and distribution lines with various grade voltage. Construction: Bare aluminum alloy 1350-H19 wires, concentrically stranded around a Class A galvanized coated steel core wire.

Get Price >>
11-4 ACSR ACSR - Overhead Transmission Conductors

11-4 ACSR ACSR - Overhead Transmission Conductors

ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. SPECIFICATIONS Southwires ACSR bare conductor meets or exceeds the following ASTM specifications: ? B230 Aluminum 1350-H19 Wire for Electrical Purposes.

Get Price >>
ACSR ?C ALUMINUM CONDUCTOR STEEL REINFORCED

ACSR ?C ALUMINUM CONDUCTOR STEEL REINFORCED

46 rows??? [short] Application: Used as bare overhead transmission cable and as primary and

Get Price >>
1-800-945-5542 - Priority Wire & Cable, Inc.

1-800-945-5542 - Priority Wire & Cable, Inc.

Application: ACSR ?C Aluminum Conductor Steel Reinforcedis used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding for desired strength to be achieved without sacrificing ampacity.

Get Price >>
6 TURKEY ACSR - ALUMINUM CONDUCTOR STEEL

6 TURKEY ACSR - ALUMINUM CONDUCTOR STEEL

Aluminum Electrical Cable Menu; Aluminum Electrical Cable. Aluminum Xhhw, Ser, Seu, Rhh Rhw-2 Xlp Use-2 . Aluminum Bare Transmission Acsr, Aac, Aac; Aluminum Medium Voltage Cable Mv-105, Mv-90, 15kv 25kv 35kv . > 6 TURKEY ACSR - ALUMINUM CONDUCTOR STEEL REINFORCED 6 TURKEY ACSR - ALUMINUM CONDUCTOR STEEL REINFORCED.

Get Price >>
AAAC ACSR AAC Conductor Production Line - jytopcable

AAAC ACSR AAC Conductor Production Line - jytopcable

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. ACSR or ACSR cable or ACSR conductor used for overhead electrical distribution and transmission lines for distributing power.

Get Price >>
ACSR - Tinde Cable

ACSR - Tinde Cable

ACSR conductors combine the light weight and good conductivity of aluminum with the high tensile strength and ruggedness of steel. In line design, this can provide higher tensions, less sag and longer span lengths than obtainable with most other types of overhead conductors. The steel strands are added as mechanical reinforcement.